ASAHI Gladius® MG / MG ES
Polymer-jacketed coronary CTO guidewire — prolapse-minimizing core · Coronary Guidewires

ASAHI Gladius® MG / MG ESProduct Code (REF): AP14R023P

ASAHI Gladius® MG extends the Gladius platform with a modified core construction designed to minimise wire prolapse — the tendency of a polymer-jacketed tip to buckle and fold back on itself when pushed against a resistant proximal cap. By resisting prolapse, Gladius MG keeps the tip aligned with the intended penetration vector, letting the operator apply forward force at fibrous caps and within the occlusion body without losing directional control. In the CTO wire escalation sequence it occupies the step where a standard middle-weight polymer wire deflects or folds, but a full stiff-wire escalation is not yet justified. The polymer jacket and hydrophilic coating preserve the low-friction tracking of the Gladius family in both antegrade and retrograde strategies. 0.014 in platform, compatible with standard coronary microcatheters.

Available under product codes AP14R023P, AP14R023S, AP14R323P, AP14R323S, AP14R024P, AP14R024S, AP14R324P, AP14R324S.

Sizes & Specifications

Diameter
0.014 in (0.36 mm)
Core
Modified prolapse-resistant design
Jacket
Full polymer jacket
Coating
Hydrophilic

Manufacturer: Asahi Intecc Co., Ltd. · Reference source: medical.asahi-intecc.com

Design & Technology

Technical characteristics and diagrams as published by Asahi Intecc.

Minimizing prolapse

Gladius MG has a modified distal core balance that minimizes a prolapse occurring in the tip.

ASAHI Gladius MG / MG ES — Minimizing prolapse diagram (official manufacturer illustration)

Excellent Durability

ASAHI Gladius MG maintains shape and guidewire performance even after crossing the lesion.

ASAHI Gladius MG / MG ES — Excellent Durability diagram (official manufacturer illustration)

High Lubricity

ASAHI Gladius MG has excellent lubricity that allows for smooth GW manipulation.

ASAHI Gladius MG / MG ES — High Lubricity diagram (official manufacturer illustration)

Torque response

ACT ONE provides better torque response with no whip motion.

ASAHI Gladius MG / MG ES — Torque response diagram (official manufacturer illustration)

The above data was obtained by company standardized test, which may differ from industry standardized tests. The data does not prove that all devices have exactly the same performance with the samples used for these tests.

Structure

Full-length structure diagram of ASAHI Gladius MG / MG ES (official manufacturer illustration)

Product Identification & Specifications

Reference identifiers for procurement, registration and tender documentation.

Product CodeAP14R023P
REF NumbersAP14R023P, AP14R023S, AP14R323P, AP14R323S, AP14R024P, AP14R024S, AP14R324P, AP14R324S
ManufacturerAsahi Intecc Co., Ltd.
BrandAsahi Intecc
Product FamilyCoronary Guidewires
Country AvailabilityTajikistan, Afghanistan

Clinical Applications

The ASAHI Gladius® MG / MG ES is a polymer-jacketed coronary cto guidewire — prolapse-minimizing core in the Coronary Guidewires family from Asahi Intecc Co., Ltd., used by interventional specialists in procedures where a polymer-jacketed coronary cto guidewire — prolapse-minimizing core of this class is indicated. It is supplied in 8 configurations (catalog codes AP14R023P through AP14R324S) to match anatomical and procedural requirements.

For the complete indications for use, contraindications and instructions for use (IFU), request the official Asahi Intecc documentation through our clinical team. Modern Medical Solutions supplies the ASAHI Gladius® MG / MG ES to hospitals and cath labs across Tajikistan and Afghanistan.

Ordering Information

Catalog reference codes as published by Asahi Intecc. Contact us to confirm current availability.

Product NameASAHI Gladius MG
Catalog No.AP14R023P
Tip ShapePre-shape
Usable Length190cm
Outer Diameter0.36mm (0.014")
Coil Length8.5cm
Radiopaque Length3cm
CoatingPolymer+Hydrophilic
Coating Length41cm
Product NameASAHI Gladius MG
Catalog No.AP14R023S
Tip ShapeStraight
Usable Length190cm
Outer Diameter0.36mm (0.014")
Coil Length8.5cm
Radiopaque Length3cm
CoatingPolymer+Hydrophilic
Coating Length41cm
Product NameASAHI Gladius MG
Catalog No.AP14R323P
Tip ShapePre-shape
Usable Length300cm
Outer Diameter0.36mm (0.014")
Coil Length8.5cm
Radiopaque Length3cm
CoatingPolymer+Hydrophilic
Coating Length41cm
Product NameASAHI Gladius MG
Catalog No.AP14R323S
Tip ShapeStraight
Usable Length300cm
Outer Diameter0.36mm (0.014")
Coil Length8.5cm
Radiopaque Length3cm
CoatingPolymer+Hydrophilic
Coating Length41cm
Product NameASAHI Gladius MG ES
Catalog No.AP14R024P
Tip ShapePre-shape
Usable Length190cm
Outer Diameter0.36mm (0.014")
Coil Length3cm
Radiopaque Length3cm
CoatingPolymer+Hydrophilic
Coating Length10cm
Product NameASAHI Gladius MG ES
Catalog No.AP14R024S
Tip ShapeStraight
Usable Length190cm
Outer Diameter0.36mm (0.014")
Coil Length3cm
Radiopaque Length3cm
CoatingPolymer+Hydrophilic
Coating Length10cm
Product NameASAHI Gladius MG ES
Catalog No.AP14R324P
Tip ShapePre-shape
Usable Length300cm
Outer Diameter0.36mm (0.014")
Coil Length3cm
Radiopaque Length3cm
CoatingPolymer+Hydrophilic
Coating Length10cm
Product NameASAHI Gladius MG ES
Catalog No.AP14R324S
Tip ShapeStraight
Usable Length300cm
Outer Diameter0.36mm (0.014")
Coil Length3cm
Radiopaque Length3cm
CoatingPolymer+Hydrophilic
Coating Length10cm

Downloads & Documentation

Instructions for use (IFU), technical datasheets and clinical literature for the ASAHI Gladius® MG / MG ES are available on request from our clinical team.

Request Documentation

Frequently Asked Questions

What is the ASAHI Gladius® MG / MG ES used for?
The ASAHI Gladius® MG / MG ES is a polymer-jacketed coronary cto guidewire — prolapse-minimizing core manufactured by Asahi Intecc, used by interventional physicians for precision vascular access procedures. Contact our clinical team for the full indications for use and instructions for use (IFU).
What sizes does the ASAHI Gladius® MG / MG ES come in?
The ASAHI Gladius® MG / MG ES is available in the following configurations: Diameter 0.014 in (0.36 mm), Core Modified prolapse-resistant design, Jacket Full polymer jacket, Coating Hydrophilic.
How can I order the ASAHI Gladius® MG / MG ES?
Modern Medical Solutions is the authorized Asahi Intecc distributor for Tajikistan and Afghanistan. Submit a documentation or ordering request through our contact form and our clinical team will confirm availability and lead time.

Related in Coronary Guidewires