Amplatzer™ Valvular Plug IIIРамзи маҳсулот (REF): 9-APVL3-042
Paravalvular leaks can be found in a variety of shapes and sizes. To tackle the leaks and fill the gaps of different morphologies, the Amplatzer Valvular Plug III is designed in a rectangular oval shape that fits a wide range of paravalvular leaks (PVL). As such, the Amplatzer Valvular Plug III can provide effective closure in over 90% of patients at 30-day follow-up. Around the world, paravalvular leaks are a common and challenging problem: paravalvular leaks occur in 7% to 17% of mitral valve replacements (MVRs) and 5% to 10% of aortic valve replacements (AVRs). By providing an effective solution to this key issue, the Amplatzer Valvular Plug III is designed for closure of paravalvular leaks adjacent to a surgically implanted heart valve. The device is offered in nine model configurations spanning waist long-axis dimensions from 4 mm to 14 mm and waist short-axis dimensions from 2 mm to 5 mm, each with a 2 mm overhang and a nominal 6.5 mm plug length (+1.0 mm / −0.5 mm).
Таҳти рамзҳои маҳсулот 9-APVL3-042, 9-APVL3-063, 9-APVL3-084, 9-APVL3-103, 9-APVL3-105, 9-APVL3-123, 9-APVL3-125, 9-APVL3-143 ва боз 1 рамзи дигар (ба бахши «Маълумот барои фармоиш» дар поён нигаред) дастрас аст.
Андозаҳо ва хусусиятҳо
- Indication
- Paravalvular leak (PVL) closure
- Shape
- Rectangular oval
- Configurations
- 4×2 mm through 14×5 mm (nine models)
- Plug length
- 6.5 mm (+1.0 mm / −0.5 mm)
Истеҳсолкунанда: Abbott Laboratories · Манбаи маълумот: cardiovascular.abbott
Тарҳ ва технология
Хусусиятҳои техникӣ ва диаграммаҳо тибқи нашрияҳои Abbott.
Ordering information

Муайянкунӣ ва хусусиятҳои маҳсулот
Идентификаторҳои истинодӣ барои харид, бақайдгирӣ ва ҳуҷҷатҳои тендерӣ.
| Рамзи маҳсулот | 9-APVL3-042 |
|---|---|
| Рақами REF | 9-APVL3-042, 9-APVL3-063, 9-APVL3-084, 9-APVL3-103, 9-APVL3-105, 9-APVL3-123, 9-APVL3-125, 9-APVL3-143, 9-APVL3-145 |
| Истеҳсолкунанда | Abbott Laboratories |
| Бренд | Abbott |
| Оилаи маҳсулот | Мудохилаҳои сохторӣ |
| Дастрасӣ аз рӯи кишварҳо | Тоҷикистон, Афғонистон |
Истифодаи клиникӣ
Amplatzer™ Valvular Plug III як transcatheter paravalvular leak closure device аз оилаи «Мудохилаҳои сохторӣ»-и истеҳсоли Abbott Laboratories мебошад, ки аз ҷониби мутахассисони мудохилавӣ дар просессҳое истифода мешавад, ки дар онҳо transcatheter paravalvular leak closure device-и ин синф нишон дода шудааст. Он дар 9 конфигуратсия (рамзҳои каталогӣ аз 9-APVL3-042 то 9-APVL3-145) барои мутобиқат бо талаботи анатомӣ ва просессӣ пешниҳод мешавад.
Барои нишондодҳои пурраи истифода, зидди нишондодҳо ва дастур оид ба истифода (IFU) ҳуҷҷатҳои расмии Abbott-ро тавассути дастаи клиникии мо дархост кунед. Modern Medical Solutions Amplatzer™ Valvular Plug III-ро ба беморхонаҳо ва лабораторияҳои катетеризатсионӣ дар саросари Тоҷикистон ва Афғонистон таъмин мекунад.
Маълумот барои фармоиш
Рамзҳои истинодии каталогӣ тибқи нашрияҳои Abbott. Барои тасдиқи мавҷудияти ҷорӣ бо мо тамос гиред.
| Model Number | Type | A — Waist Long Axis (mm) | B — Waist Short Axis (mm) | C — Overhang (mm) | D — Plug Length (mm) |
|---|---|---|---|---|---|
| 9-APVL3-042 | 4x2 mm | 4 | 2 | 2 | 6.5 |
| 9-APVL3-063 | 6x3 mm | 6 | 3 | 2 | 6.5 |
| 9-APVL3-084 | 8x4 mm | 8 | 4 | 2 | 6.5 |
| 9-APVL3-103 | 10x3 mm | 10 | 3 | 2 | 6.5 |
| 9-APVL3-105 | 10x5 mm | 10 | 5 | 2 | 6.5 |
| 9-APVL3-123 | 12x3 mm | 12 | 3 | 2 | 6.5 |
| 9-APVL3-125 | 12x5 mm | 12 | 5 | 2 | 6.5 |
| 9-APVL3-143 | 14x3 mm | 14 | 3 | 2 | 6.5 |
| 9-APVL3-145 | 14x5 mm | 14 | 5 | 2 | 6.5 |
Model numbers and dimensions per the official Abbott Amplatzer™ Valvular Plug III product page ordering information. A = waist long axis, B = waist short axis, C = overhang, D = plug length (+1.0 mm / −0.5 mm).
Ҳуҷҷатҳо ва маводҳо
Дастур оид ба истифода (IFU), варақаҳои техникӣ ва адабиёти клиникӣ барои Amplatzer™ Valvular Plug III аз рӯи дархост аз дастаи клиникии мо дастрас аст.
Дархости ҳуҷҷатҳоСаволҳои зуд-зуд додашаванда
- What is the Amplatzer™ Valvular Plug III used for?
- The Amplatzer™ Valvular Plug III is a transcatheter device for closure of paravalvular leaks (PVL) adjacent to a surgically implanted heart valve. It is designed in a rectangular oval shape that fits a wide range of PVL morphologies.
- How common are paravalvular leaks?
- Paravalvular leaks are a common and challenging problem. They occur in 7% to 17% of mitral valve replacements (MVRs) and 5% to 10% of aortic valve replacements (AVRs).
- What closure rate does the source page report?
- As stated on the Abbott source page, the Amplatzer Valvular Plug III can provide effective closure in over 90% of patients at 30-day follow-up.
- What sizes are available?
- The device is offered in nine model configurations, from 9-APVL3-042 (4×2 mm) to 9-APVL3-145 (14×5 mm). Each has a 2 mm overhang and a nominal plug length of 6.5 mm (+1.0 mm / −0.5 mm).