Amplatzer™ Valvular Plug IIIProduct Code (REF): 9-APVL3-042
Paravalvular leaks can be found in a variety of shapes and sizes. To tackle the leaks and fill the gaps of different morphologies, the Amplatzer Valvular Plug III is designed in a rectangular oval shape that fits a wide range of paravalvular leaks (PVL). As such, the Amplatzer Valvular Plug III can provide effective closure in over 90% of patients at 30-day follow-up. Around the world, paravalvular leaks are a common and challenging problem: paravalvular leaks occur in 7% to 17% of mitral valve replacements (MVRs) and 5% to 10% of aortic valve replacements (AVRs). By providing an effective solution to this key issue, the Amplatzer Valvular Plug III is designed for closure of paravalvular leaks adjacent to a surgically implanted heart valve. The device is offered in nine model configurations spanning waist long-axis dimensions from 4 mm to 14 mm and waist short-axis dimensions from 2 mm to 5 mm, each with a 2 mm overhang and a nominal 6.5 mm plug length (+1.0 mm / −0.5 mm).
Available under product codes 9-APVL3-042, 9-APVL3-063, 9-APVL3-084, 9-APVL3-103, 9-APVL3-105, 9-APVL3-123, 9-APVL3-125, 9-APVL3-143 and 1 more (see Ordering Information below).
Sizes & Specifications
- Indication
- Paravalvular leak (PVL) closure
- Shape
- Rectangular oval
- Configurations
- 4×2 mm through 14×5 mm (nine models)
- Plug length
- 6.5 mm (+1.0 mm / −0.5 mm)
Manufacturer: Abbott Laboratories · Reference source: cardiovascular.abbott
Design & Technology
Technical characteristics and diagrams as published by Abbott.
Ordering information

Product Identification & Specifications
Reference identifiers for procurement, registration and tender documentation.
| Product Code | 9-APVL3-042 |
|---|---|
| REF Numbers | 9-APVL3-042, 9-APVL3-063, 9-APVL3-084, 9-APVL3-103, 9-APVL3-105, 9-APVL3-123, 9-APVL3-125, 9-APVL3-143, 9-APVL3-145 |
| Manufacturer | Abbott Laboratories |
| Brand | Abbott |
| Product Family | Structural Interventions |
| Country Availability | Tajikistan, Afghanistan |
Clinical Applications
The Amplatzer™ Valvular Plug III is a transcatheter paravalvular leak closure device in the Structural Interventions family from Abbott Laboratories, used by interventional specialists in procedures where a transcatheter paravalvular leak closure device of this class is indicated. It is supplied in 9 configurations (catalog codes 9-APVL3-042 through 9-APVL3-145) to match anatomical and procedural requirements.
For the complete indications for use, contraindications and instructions for use (IFU), request the official Abbott documentation through our clinical team. Modern Medical Solutions supplies the Amplatzer™ Valvular Plug III to hospitals and cath labs across Tajikistan and Afghanistan.
Ordering Information
Catalog reference codes as published by Abbott. Contact us to confirm current availability.
| Model Number | Type | A — Waist Long Axis (mm) | B — Waist Short Axis (mm) | C — Overhang (mm) | D — Plug Length (mm) |
|---|---|---|---|---|---|
| 9-APVL3-042 | 4x2 mm | 4 | 2 | 2 | 6.5 |
| 9-APVL3-063 | 6x3 mm | 6 | 3 | 2 | 6.5 |
| 9-APVL3-084 | 8x4 mm | 8 | 4 | 2 | 6.5 |
| 9-APVL3-103 | 10x3 mm | 10 | 3 | 2 | 6.5 |
| 9-APVL3-105 | 10x5 mm | 10 | 5 | 2 | 6.5 |
| 9-APVL3-123 | 12x3 mm | 12 | 3 | 2 | 6.5 |
| 9-APVL3-125 | 12x5 mm | 12 | 5 | 2 | 6.5 |
| 9-APVL3-143 | 14x3 mm | 14 | 3 | 2 | 6.5 |
| 9-APVL3-145 | 14x5 mm | 14 | 5 | 2 | 6.5 |
Model numbers and dimensions per the official Abbott Amplatzer™ Valvular Plug III product page ordering information. A = waist long axis, B = waist short axis, C = overhang, D = plug length (+1.0 mm / −0.5 mm).
Downloads & Documentation
Instructions for use (IFU), technical datasheets and clinical literature for the Amplatzer™ Valvular Plug III are available on request from our clinical team.
Request DocumentationFrequently Asked Questions
- What is the Amplatzer™ Valvular Plug III used for?
- The Amplatzer™ Valvular Plug III is a transcatheter device for closure of paravalvular leaks (PVL) adjacent to a surgically implanted heart valve. It is designed in a rectangular oval shape that fits a wide range of PVL morphologies.
- How common are paravalvular leaks?
- Paravalvular leaks are a common and challenging problem. They occur in 7% to 17% of mitral valve replacements (MVRs) and 5% to 10% of aortic valve replacements (AVRs).
- What closure rate does the source page report?
- As stated on the Abbott source page, the Amplatzer Valvular Plug III can provide effective closure in over 90% of patients at 30-day follow-up.
- What sizes are available?
- The device is offered in nine model configurations, from 9-APVL3-042 (4×2 mm) to 9-APVL3-145 (14×5 mm). Each has a 2 mm overhang and a nominal plug length of 6.5 mm (+1.0 mm / −0.5 mm).