FRED™
Flow diverter · Стентҳо ва дастгоҳҳои тағйири ҷараён

FRED™Рамзи маҳсулот (REF): FRED3507

FRED™ (Flow Re-Direction Endoluminal Device) is MicroVention's dual-layer flow-diverting stent for the endovascular treatment of large and giant cerebral aneurysms that are unsuitable for coiling alone. The device consists of a higher-density inner mesh that creates a flow-diverting metallic surface across the aneurysm neck — redirecting blood away from the sac and promoting progressive thrombosis and neointimal healing — mounted on a lower-density outer scaffold that provides radial force and allows flow through covered perforators and side branches. FRED's dual-layer architecture is engineered to decouple the competing requirements of flow diversion (high metallic surface area density) and branch preservation (low metallic coverage over perforators). The outer layer has sufficient open area for branch vessel flow while the inner layer concentrates coverage at the aneurysm neck. The device self-expands immediately upon release and opens predictably without the foreshortening variability that affects some competitive platforms. Deployment is made via the Headway 27 microcatheter. FRED is available in implant diameters from 3.5 mm to 5.5 mm, with working lengths from 7 mm to 58 mm depending on the target vessel diameter chosen for sizing. Catalog numbers span FRED3507 (3.5 mm / 7 mm working length) through FRED5526 (5.5 mm / 26 mm working length).

Таҳти рамзҳои маҳсулот FRED3507, FRED3511, FRED3516, FRED3524, FRED3536, FRED4007, FRED4012, FRED4017 ва боз 13 рамзи дигар (ба бахши «Маълумот барои фармоиш» дар поён нигаред) дастрас аст.

Андозаҳо ва хусусиятҳо

Implant diameter
3.5 mm – 5.5 mm
Delivery microcatheter
Headway 27
Working / total length
7 mm – 58 mm working

Истеҳсолкунанда: Terumo Neuro (MicroVention, Inc.) · Манбаи маълумот: terumoneuro.com

Тарҳ ва технология

Хусусиятҳои техникӣ ва диаграммаҳо тибқи нашрияҳои Terumo Neuro (MicroVention).

The FRED™ and FRED™ Jr. flow diversion devices feature a unique dual layer construction designed to achieve excellent vessel wall apposition, which fosters neointimal growth and long-term aneurysm occlusion. The FRED™ Jr. is optimized for distal locations. Both devices may be used with or without embolic coils.

FRED™ — official product image (Terumo Neuro)

Immediate Opening

Innovative and elegant device design results in easy device sizing, deployment, and device opening

Precise, Predictable Placement

Consistent device opening and ability to recapture and reposition for precise placement

Effective

Dual action design provides vessel wall stability and conformance for effective flow diversion

Муайянкунӣ ва хусусиятҳои маҳсулот

Идентификаторҳои истинодӣ барои харид, бақайдгирӣ ва ҳуҷҷатҳои тендерӣ.

Рамзи маҳсулотFRED3507
Рақами REFFRED3507, FRED3511, FRED3516, FRED3524, FRED3536, FRED4007, FRED4012, FRED4017, FRED4026, FRED4038, FRED4508, FRED4513, FRED4518, FRED4528, FRED4539, FRED5009, FRED5014, FRED5019, FRED5029, FRED5514, FRED5526
ИстеҳсолкунандаTerumo Neuro (MicroVention, Inc.)
БрендTerumo Neuro (MicroVention)
Оилаи маҳсулотСтентҳо ва дастгоҳҳои тағйири ҷараён
Дастрасӣ аз рӯи кишварҳоТоҷикистон, Афғонистон

Истифодаи клиникӣ

FRED™ як flow diverter аз оилаи «Стентҳо ва дастгоҳҳои тағйири ҷараён»-и истеҳсоли Terumo Neuro (MicroVention, Inc.) мебошад, ки аз ҷониби мутахассисони мудохилавӣ дар просессҳое истифода мешавад, ки дар онҳо flow diverter-и ин синф нишон дода шудааст. Он дар 21 конфигуратсия (рамзҳои каталогӣ аз FRED3507 то FRED5526) барои мутобиқат бо талаботи анатомӣ ва просессӣ пешниҳод мешавад.

Барои нишондодҳои пурраи истифода, зидди нишондодҳо ва дастур оид ба истифода (IFU) ҳуҷҷатҳои расмии Terumo Neuro (MicroVention)-ро тавассути дастаи клиникии мо дархост кунед. Modern Medical Solutions FRED™-ро ба беморхонаҳо ва лабораторияҳои катетеризатсионӣ дар саросари Тоҷикистон ва Афғонистон таъмин мекунад.

Маълумот барои фармоиш

Рамзҳои истинодии каталогӣ тибқи нашрияҳои Terumo Neuro (MicroVention). Барои тасдиқи мавҷудияти ҷорӣ бо мо тамос гиред.

Catalog #FRED3507
Implant Diameter (mm)3.5
Working Length / Total Length by Target Vessel (mm)3.0mm: 10/16 · 3.5mm: 7/13
Catalog #FRED3511
Implant Diameter (mm)3.5
Working Length / Total Length by Target Vessel (mm)3.0mm: 17/22 · 3.5mm: 11/17
Catalog #FRED3516
Implant Diameter (mm)3.5
Working Length / Total Length by Target Vessel (mm)3.0mm: 24/30 · 3.5mm: 16/22
Catalog #FRED3524
Implant Diameter (mm)3.5
Working Length / Total Length by Target Vessel (mm)3.0mm: 34/40 · 3.5mm: 24/31
Catalog #FRED3536
Implant Diameter (mm)3.5
Working Length / Total Length by Target Vessel (mm)3.0mm: 49/54 · 3.5mm: 36/40
Catalog #FRED4007
Implant Diameter (mm)4.0
Working Length / Total Length by Target Vessel (mm)3.5mm: 10/16 · 4.0mm: 7/13
Catalog #FRED4012
Implant Diameter (mm)4.0
Working Length / Total Length by Target Vessel (mm)3.5mm: 18/24 · 4.0mm: 12/18
Catalog #FRED4017
Implant Diameter (mm)4.0
Working Length / Total Length by Target Vessel (mm)3.5mm: 26/31 · 4.0mm: 17/23
Catalog #FRED4026
Implant Diameter (mm)4.0
Working Length / Total Length by Target Vessel (mm)3.5mm: 37/43 · 4.0mm: 26/32
Catalog #FRED4038
Implant Diameter (mm)4.0
Working Length / Total Length by Target Vessel (mm)3.5mm: 53/58 · 4.0mm: 38/44
Catalog #FRED4508
Implant Diameter (mm)4.5
Working Length / Total Length by Target Vessel (mm)4.0mm: 11/18 · 4.5mm: 8/15
Catalog #FRED4513
Implant Diameter (mm)4.5
Working Length / Total Length by Target Vessel (mm)4.0mm: 19/26 · 4.5mm: 13/20
Catalog #FRED4518
Implant Diameter (mm)4.5
Working Length / Total Length by Target Vessel (mm)4.0mm: 27/34 · 4.5mm: 18/25
Catalog #FRED4528
Implant Diameter (mm)4.5
Working Length / Total Length by Target Vessel (mm)4.0mm: 39/45 · 4.5mm: 28/34
Catalog #FRED4539
Implant Diameter (mm)4.5
Working Length / Total Length by Target Vessel (mm)4.0mm: 56/62 · 4.5mm: 39/45
Catalog #FRED5009
Implant Diameter (mm)5.0
Working Length / Total Length by Target Vessel (mm)4.5mm: 12/18 · 5.0mm: 9/15
Catalog #FRED5014
Implant Diameter (mm)5.0
Working Length / Total Length by Target Vessel (mm)4.5mm: 20/26 · 5.0mm: 14/21
Catalog #FRED5019
Implant Diameter (mm)5.0
Working Length / Total Length by Target Vessel (mm)4.5mm: 28/35 · 5.0mm: 19/26
Catalog #FRED5029
Implant Diameter (mm)5.0
Working Length / Total Length by Target Vessel (mm)4.5mm: 41/48 · 5.0mm: 29/36
Catalog #FRED5514
Implant Diameter (mm)5.5
Working Length / Total Length by Target Vessel (mm)5.0mm: 22/28 · 5.5mm: 14/22
Catalog #FRED5526
Implant Diameter (mm)5.5
Working Length / Total Length by Target Vessel (mm)5.0mm: 38/46 · 5.5mm: 26/32

Ҳуҷҷатҳо ва маводҳо

Дастур оид ба истифода (IFU), варақаҳои техникӣ ва адабиёти клиникӣ барои FRED™ аз рӯи дархост аз дастаи клиникии мо дастрас аст.

Дархости ҳуҷҷатҳо

Саволҳои зуд-зуд додашаванда

What is the FRED™ flow diverter and what does it treat?
FRED™ (Flow Re-Direction Endoluminal Device) is a dual-layer, self-expanding flow diverter for the endovascular treatment of large and giant intracranial aneurysms. It is placed in the parent artery spanning the aneurysm neck, redirecting blood flow away from the sac to cause progressive thrombosis and neointimal healing. FRED is particularly indicated for fusiform, wide-neck, and large saccular aneurysms where coiling alone achieves insufficient occlusion.
What sizes does FRED™ come in?
FRED™ is available in implant diameters from 3.5 mm to 5.5 mm (3.5, 4.0, 4.5, 5.0, 5.5 mm). Working lengths range from 7 mm to 58 mm depending on the target vessel diameter used for sizing. Catalog numbers run from FRED3507 (3.5 mm implant diameter, 7 mm working length) through FRED5526 (5.5 mm, 26 mm working length). All FRED devices are delivered via Headway 27 microcatheter.
What is the difference between FRED™ and FRED™ X?
FRED X adds X Technology — a nanoscale surface treatment covalently bonded to the nitinol strands — to reduce material thrombogenicity at the blood-device interface. FRED X also extends the size range downward to 2.5 mm (for distal/smaller vessel aneurysms) and features reduced delivery and retraction forces for improved navigability in tortuous anatomy. FRED X is the current-generation device; the original FRED is the established predecessor.
What microcatheter is used to deliver FRED™?
FRED™ (3.5–5.5 mm sizes) is delivered via the Headway 27 microcatheter (0.027 in inner diameter). FRED X in the smaller 2.5–3.0 mm System 21 variants is delivered via Headway 21 (0.021 in); the 3.5–5.5 mm System 27 variants via Headway 27. The delivery system requires a standard 6Fr guide catheter or long sheath.
Does FRED™ require antiplatelet therapy?
Yes. Like all flow diverters, FRED requires dual antiplatelet therapy (DAPT) — typically aspirin and clopidogrel or ticagrelor — started before the procedure and continued for a period defined by the treating physician. Antiplatelet protocols are physician-determined; FRED X’s X Technology is designed to reduce material thrombogenicity but does not eliminate the need for antiplatelet management.

Марбут дар «Стентҳо ва дастгоҳҳои тағйири ҷараён»