Abbott Amplatzer transcatheter septal occluders for ASD closure
Transcatheter ASD closure device family · Structural Interventions

Amplatzer™ Septal OccludersProduct Code (REF): 9-ASD-004

Amplatzer™ Septal Occluders are the standard of care for minimally invasive atrial septal defect (ASD) closure. These double-disc occluders are comprised of nitinol mesh and polyester material, and are designed to securely appose the septal wall on each side of the defect and create a platform for tissue in-growth after implantation. Atrial septal defects come in a variety of shapes and sizes, and there can often be multiple, or fenestrated, ASDs. The Amplatzer™ Septal Occluder has a wide waist that centers the device and fills the ASD for optimal occlusion; its transcatheter delivery makes it the proven standard of care for the occlusion of ASDs. The Amplatzer™ Multifenestrated Septal Occluder “Cribriform” has a narrow waist, which allows for placement through a central defect, and matched disc diameters that maximize coverage of multiple fenestrations — enabling occlusion of the defect by covering the fenestrations with a single device.

Available under product codes 9-ASD-004, 9-ASD-005, 9-ASD-006, 9-ASD-007, 9-ASD-008, 9-ASD-009, 9-ASD-010, 9-ASD-011 and 24 more (see Ordering Information below).

Sizes & Specifications

Indication
Atrial septal defect (ASD) closure
Construction
Nitinol mesh and polyester material
Septal Occluder waist range
4–40 mm
Cribriform disc range
18–40 mm (3 mm waist width)

Manufacturer: Abbott Laboratories · Reference source: cardiovascular.abbott

Design & Technology

Technical characteristics and diagrams as published by Abbott.

Amplatzer™ Cribriform Multi-Fenestrated Septal Occluder

The Amplatzer™ Cribriform Occluder has a narrow waist, which allows for placement through a central defect, and matched disc diameters that maximize coverage of multiple fenestrations, enabling occlusion by covering the fenestrations with a single device.

Official Abbott product image of the Amplatzer Cribriform multi-fenestrated septal occluder

Product Identification & Specifications

Reference identifiers for procurement, registration and tender documentation.

Product Code9-ASD-004
REF Numbers9-ASD-004, 9-ASD-005, 9-ASD-006, 9-ASD-007, 9-ASD-008, 9-ASD-009, 9-ASD-010, 9-ASD-011, 9-ASD-012, 9-ASD-013, 9-ASD-014, 9-ASD-015, 9-ASD-016, 9-ASD-017, 9-ASD-018, 9-ASD-019, 9-ASD-020, 9-ASD-022, 9-ASD-024, 9-ASD-026, 9-ASD-028, 9-ASD-030, 9-ASD-032, 9-ASD-034, 9-ASD-036, 9-ASD-038, 9-ASD-040, 9-ASD-MF-018, 9-ASD-MF-025, 9-ASD-MF-030, 9-ASD-MF-035, 9-ASD-MF-040
ManufacturerAbbott Laboratories
BrandAbbott
Product FamilyStructural Interventions
Country AvailabilityTajikistan, Afghanistan

Clinical Applications

The Amplatzer™ Septal Occluders is a transcatheter asd closure device family in the Structural Interventions family from Abbott Laboratories, used by interventional specialists in procedures where a transcatheter asd closure device family of this class is indicated. It is supplied in 32 configurations (catalog codes 9-ASD-004 through 9-ASD-MF-040) to match anatomical and procedural requirements.

For the complete indications for use, contraindications and instructions for use (IFU), request the official Abbott documentation through our clinical team. Modern Medical Solutions supplies the Amplatzer™ Septal Occluders to hospitals and cath labs across Tajikistan and Afghanistan.

Ordering Information

Catalog reference codes as published by Abbott. Contact us to confirm current availability.

Amplatzer™ Septal Occluder

Model/Reorder Number9-ASD-004
Waist Diameter (mm)4
Waist Width (mm)3
Right Atrial Disc Diameter (mm)12
Left Atrial Disc Diameter (mm)16
Model/Reorder Number9-ASD-005
Waist Diameter (mm)5
Waist Width (mm)3
Right Atrial Disc Diameter (mm)13
Left Atrial Disc Diameter (mm)17
Model/Reorder Number9-ASD-006
Waist Diameter (mm)6
Waist Width (mm)3
Right Atrial Disc Diameter (mm)14
Left Atrial Disc Diameter (mm)18
Model/Reorder Number9-ASD-007
Waist Diameter (mm)7
Waist Width (mm)3
Right Atrial Disc Diameter (mm)15
Left Atrial Disc Diameter (mm)19
Model/Reorder Number9-ASD-008
Waist Diameter (mm)8
Waist Width (mm)3
Right Atrial Disc Diameter (mm)16
Left Atrial Disc Diameter (mm)20
Model/Reorder Number9-ASD-009
Waist Diameter (mm)9
Waist Width (mm)3
Right Atrial Disc Diameter (mm)17
Left Atrial Disc Diameter (mm)21
Model/Reorder Number9-ASD-010
Waist Diameter (mm)10
Waist Width (mm)3
Right Atrial Disc Diameter (mm)18
Left Atrial Disc Diameter (mm)22
Model/Reorder Number9-ASD-011
Waist Diameter (mm)11
Waist Width (mm)4
Right Atrial Disc Diameter (mm)21
Left Atrial Disc Diameter (mm)25
Model/Reorder Number9-ASD-012
Waist Diameter (mm)12
Waist Width (mm)4
Right Atrial Disc Diameter (mm)22
Left Atrial Disc Diameter (mm)26
Model/Reorder Number9-ASD-013
Waist Diameter (mm)13
Waist Width (mm)4
Right Atrial Disc Diameter (mm)23
Left Atrial Disc Diameter (mm)27
Model/Reorder Number9-ASD-014
Waist Diameter (mm)14
Waist Width (mm)4
Right Atrial Disc Diameter (mm)24
Left Atrial Disc Diameter (mm)28
Model/Reorder Number9-ASD-015
Waist Diameter (mm)15
Waist Width (mm)4
Right Atrial Disc Diameter (mm)25
Left Atrial Disc Diameter (mm)29
Model/Reorder Number9-ASD-016
Waist Diameter (mm)16
Waist Width (mm)4
Right Atrial Disc Diameter (mm)26
Left Atrial Disc Diameter (mm)30
Model/Reorder Number9-ASD-017
Waist Diameter (mm)17
Waist Width (mm)4
Right Atrial Disc Diameter (mm)27
Left Atrial Disc Diameter (mm)31
Model/Reorder Number9-ASD-018
Waist Diameter (mm)18
Waist Width (mm)4
Right Atrial Disc Diameter (mm)28
Left Atrial Disc Diameter (mm)32
Model/Reorder Number9-ASD-019
Waist Diameter (mm)19
Waist Width (mm)4
Right Atrial Disc Diameter (mm)29
Left Atrial Disc Diameter (mm)33
Model/Reorder Number9-ASD-020
Waist Diameter (mm)20
Waist Width (mm)4
Right Atrial Disc Diameter (mm)30
Left Atrial Disc Diameter (mm)34
Model/Reorder Number9-ASD-022
Waist Diameter (mm)22
Waist Width (mm)4
Right Atrial Disc Diameter (mm)32
Left Atrial Disc Diameter (mm)36
Model/Reorder Number9-ASD-024
Waist Diameter (mm)24
Waist Width (mm)4
Right Atrial Disc Diameter (mm)34
Left Atrial Disc Diameter (mm)38
Model/Reorder Number9-ASD-026
Waist Diameter (mm)26
Waist Width (mm)4
Right Atrial Disc Diameter (mm)36
Left Atrial Disc Diameter (mm)40
Model/Reorder Number9-ASD-028
Waist Diameter (mm)28
Waist Width (mm)4
Right Atrial Disc Diameter (mm)38
Left Atrial Disc Diameter (mm)42
Model/Reorder Number9-ASD-030
Waist Diameter (mm)30
Waist Width (mm)4
Right Atrial Disc Diameter (mm)40
Left Atrial Disc Diameter (mm)44
Model/Reorder Number9-ASD-032
Waist Diameter (mm)32
Waist Width (mm)4
Right Atrial Disc Diameter (mm)42
Left Atrial Disc Diameter (mm)46
Model/Reorder Number9-ASD-034
Waist Diameter (mm)34
Waist Width (mm)4
Right Atrial Disc Diameter (mm)44
Left Atrial Disc Diameter (mm)50
Model/Reorder Number9-ASD-036
Waist Diameter (mm)36
Waist Width (mm)4
Right Atrial Disc Diameter (mm)46
Left Atrial Disc Diameter (mm)52
Model/Reorder Number9-ASD-038
Waist Diameter (mm)38
Waist Width (mm)4
Right Atrial Disc Diameter (mm)48
Left Atrial Disc Diameter (mm)54
Model/Reorder Number9-ASD-040
Waist Diameter (mm)40
Waist Width (mm)4
Right Atrial Disc Diameter (mm)50
Left Atrial Disc Diameter (mm)56

Amplatzer™ Cribriform Multi-Fenestrated Septal Occluder

Model/Reorder Number9-ASD-MF-018
Right & Left Atrium Disc Diameter (mm)18
Waist Width (mm)3
Model/Reorder Number9-ASD-MF-025
Right & Left Atrium Disc Diameter (mm)25
Waist Width (mm)3
Model/Reorder Number9-ASD-MF-030
Right & Left Atrium Disc Diameter (mm)30
Waist Width (mm)3
Model/Reorder Number9-ASD-MF-035
Right & Left Atrium Disc Diameter (mm)35
Waist Width (mm)3
Model/Reorder Number9-ASD-MF-040
Right & Left Atrium Disc Diameter (mm)40
Waist Width (mm)3

Model/Reorder numbers and dimensions per the official Abbott Amplatzer™ Septal Occluders product page ordering information.

Downloads & Documentation

Instructions for use (IFU), technical datasheets and clinical literature for the Amplatzer™ Septal Occluders are available on request from our clinical team.

Request Documentation

Frequently Asked Questions

What are Amplatzer™ Septal Occluders?
Amplatzer™ Septal Occluders are double-disc occluders for minimally invasive closure of atrial septal defects (ASD). They are comprised of nitinol mesh and polyester material, designed to securely appose the septal wall on each side of the defect and create a platform for tissue in-growth after implantation.
How does the Cribriform occluder differ from the standard Septal Occluder?
The Amplatzer™ Septal Occluder has a wide waist that centers the device and fills the ASD for optimal occlusion. The Amplatzer™ Cribriform Multi-Fenestrated Septal Occluder instead has a narrow waist that allows placement through a central defect, with matched disc diameters that maximize coverage of multiple fenestrations.
When is the Cribriform occluder used?
The Cribriform occluder is intended for multiple, or fenestrated, ASDs. Its matched disc diameters enable occlusion of the defect by covering the fenestrations with a single device.
What sizes are available for the Amplatzer™ Septal Occluder?
The Amplatzer™ Septal Occluder is offered across waist diameters from 4 mm (9-ASD-004) to 40 mm (9-ASD-040). The Cribriform occluder is offered in matched right and left atrium disc diameters of 18, 25, 30, 35 and 40 mm, each with a 3 mm waist width.

Related in Structural Interventions