Masters Series Mechanical Heart ValveРамзи маҳсулот (REF): 15AHPJ-505
The Masters Series mechanical heart valves are rotatable, bileaflet valves designed for implantation in the aortic or mitral position. Abbott minimizes valve bulk with the sleek Pivot Guard design paired with sewing cuff options that maximize implantability without extraneous material. The Masters Series was designed with low thrombogenicity at the forefront: minimized carbon surface area can lessen thrombus formation, large internal diameters up to 26.1 mm promote low pressure gradients — which can help minimize shear stress and thrombogenicity — and uniform velocities within the hinge recesses help aid washout of blood elements. The Masters HP series brings hemodynamics and implantability together in both the aortic and mitral position, and is now available also for babies and newborns. The 15 mm Masters HP Mitral and Aortic Valve is the world's smallest mechanical heart valve, making it possible to treat the tiniest patients, including newborns and babies. The Masters Series offers a broad range of cuff options — HP standard and expanded cuffs, polyester standard and expanded cuffs, and PTFE cuffs — to tailor implantation to every patient across both the aortic and mitral positions.
Таҳти рамзҳои маҳсулот 15AHPJ-505, 17AHPJ-505, 17AEHPJ-505, 19AHPJ-505, 19AEHPJ-505, 19AJ-501, 19AECJ-502, 19ATJ-503 ва боз 67 рамзи дигар (ба бахши «Маълумот барои фармоиш» дар поён нигаред) дастрас аст.
Андозаҳо ва хусусиятҳо
- Valve type
- Aortic and mitral bileaflet mechanical valves
- Positions
- Aortic and mitral
- Smallest size
- 15 mm (Masters HP)
- Internal diameter
- up to 26.1 mm
Истеҳсолкунанда: Abbott Laboratories · Манбаи маълумот: cardiovascular.abbott
Тарҳ ва технология
Хусусиятҳои техникӣ ва диаграммаҳо тибқи нашрияҳои Abbott.
The Regent™, Masters HP and Masters family

Муайянкунӣ ва хусусиятҳои маҳсулот
Идентификаторҳои истинодӣ барои харид, бақайдгирӣ ва ҳуҷҷатҳои тендерӣ.
| Рамзи маҳсулот | 15AHPJ-505 |
|---|---|
| Рақами REF | 15AHPJ-505, 17AHPJ-505, 17AEHPJ-505, 19AHPJ-505, 19AEHPJ-505, 19AJ-501, 19AECJ-502, 19ATJ-503, 21AHPJ-505, 21AEHPJ-505, 21AJ-501, 21AECJ-502, 21ATJ-503, 23AHPJ-505, 23AEHPJ-505, 23AJ-501, 23AECJ-502, 23ATJ-503, 25AHPJ-505, 25AEHPJ-505, 25AJ-501, 25AECJ-502, 25ATJ-503, 27AHPJ-505, 27AEHPJ-505, 27AJ-501, 27AECJ-502, 27ATJ-503, 29AJ-501, 29AECJ-502, 29ATJ-503, 31AJ-501, 31AECJ-502, 31ATJ-503, 15MHPJ-505, 17MHPJ-505, 19MHPJ-505, 19MJ-501, 19MECJ-502, 19MTJ-503, 19METJ-504, 21MHPJ-505, 21MJ-501, 21MECJ-502, 21MTJ-503, 21METJ-504, 23MHPJ-505, 23MJ-501, 23MECJ-502, 23MTJ-503, 23METJ-504, 25MHPJ-505, 25MJ-501, 25MECJ-502, 25MTJ-503, 25METJ-504, 27MHPJ-505, 27MJ-501, 27MECJ-502, 27MTJ-503, 27METJ-504, 29MJ-501, 29MECJ-502, 29MTJ-503, 29METJ-504, 31MJ-501, 31MECJ-502, 31MTJ-503, 31METJ-504, 33MJ-501, 33MECJ-502, 33MTJ-503, 33METJ-504, 35MJ-501, 37MJ-501 |
| Истеҳсолкунанда | Abbott Laboratories |
| Бренд | Abbott |
| Оилаи маҳсулот | Клапанҳои ҷарроҳии дил |
| Дастрасӣ аз рӯи кишварҳо | Тоҷикистон, Афғонистон |
Истифодаи клиникӣ
Masters Series Mechanical Heart Valve як aortic and mitral bileaflet mechanical heart valves аз оилаи «Клапанҳои ҷарроҳии дил»-и истеҳсоли Abbott Laboratories мебошад, ки аз ҷониби мутахассисони мудохилавӣ дар просессҳое истифода мешавад, ки дар онҳо aortic and mitral bileaflet mechanical heart valves-и ин синф нишон дода шудааст. Он дар 75 конфигуратсия (рамзҳои каталогӣ аз 15AHPJ-505 то 37MJ-501) барои мутобиқат бо талаботи анатомӣ ва просессӣ пешниҳод мешавад.
Барои нишондодҳои пурраи истифода, зидди нишондодҳо ва дастур оид ба истифода (IFU) ҳуҷҷатҳои расмии Abbott-ро тавассути дастаи клиникии мо дархост кунед. Modern Medical Solutions Masters Series Mechanical Heart Valve-ро ба беморхонаҳо ва лабораторияҳои катетеризатсионӣ дар саросари Тоҷикистон ва Афғонистон таъмин мекунад.
Маълумот барои фармоиш
Рамзҳои истинодии каталогӣ тибқи нашрияҳои Abbott. Барои тасдиқи мавҷудияти ҷорӣ бо мо тамос гиред.
| Position | Size (mm) | Masters HP Standard Cuff Catalog No. | Masters HP Expanded Cuff Catalog No. | Masters Polyester Standard Cuff Catalog No. | Masters Polyester Expanded Cuff Catalog No. | Masters PTFE Cuff Catalog No. | Masters Expanded PTFE Cuff Catalog No. |
|---|---|---|---|---|---|---|---|
| Aortic | 15 | 15AHPJ-505 | — | — | — | — | — |
| Aortic | 17 | 17AHPJ-505 | 17AEHPJ-505 | — | — | — | — |
| Aortic | 19 | 19AHPJ-505 | 19AEHPJ-505 | 19AJ-501 | 19AECJ-502 | 19ATJ-503 | — |
| Aortic | 21 | 21AHPJ-505 | 21AEHPJ-505 | 21AJ-501 | 21AECJ-502 | 21ATJ-503 | — |
| Aortic | 23 | 23AHPJ-505 | 23AEHPJ-505 | 23AJ-501 | 23AECJ-502 | 23ATJ-503 | — |
| Aortic | 25 | 25AHPJ-505 | 25AEHPJ-505 | 25AJ-501 | 25AECJ-502 | 25ATJ-503 | — |
| Aortic | 27 | 27AHPJ-505 | 27AEHPJ-505 | 27AJ-501 | 27AECJ-502 | 27ATJ-503 | — |
| Aortic | 29 | — | — | 29AJ-501 | 29AECJ-502 | 29ATJ-503 | — |
| Aortic | 31 | — | — | 31AJ-501 | 31AECJ-502 | 31ATJ-503 | — |
| Mitral | 15 | 15MHPJ-505 | — | — | — | — | — |
| Mitral | 17 | 17MHPJ-505 | — | — | — | — | — |
| Mitral | 19 | 19MHPJ-505 | — | 19MJ-501 | 19MECJ-502 | 19MTJ-503 | 19METJ-504 |
| Mitral | 21 | 21MHPJ-505 | — | 21MJ-501 | 21MECJ-502 | 21MTJ-503 | 21METJ-504 |
| Mitral | 23 | 23MHPJ-505 | — | 23MJ-501 | 23MECJ-502 | 23MTJ-503 | 23METJ-504 |
| Mitral | 25 | 25MHPJ-505 | — | 25MJ-501 | 25MECJ-502 | 25MTJ-503 | 25METJ-504 |
| Mitral | 27 | 27MHPJ-505 | — | 27MJ-501 | 27MECJ-502 | 27MTJ-503 | 27METJ-504 |
| Mitral | 29 | — | — | 29MJ-501 | 29MECJ-502 | 29MTJ-503 | 29METJ-504 |
| Mitral | 31 | — | — | 31MJ-501 | 31MECJ-502 | 31MTJ-503 | 31METJ-504 |
| Mitral | 33 | — | — | 33MJ-501 | 33MECJ-502 | 33MTJ-503 | 33METJ-504 |
| Mitral | 35 | — | — | 35MJ-501 | — | — | — |
| Mitral | 37 | — | — | 37MJ-501 | — | — | — |
Catalog numbers from the Valve Ordering Guide in Abbott's official mechanical heart valve EMEA brochure, cross-referenced with Masters Series product information. Confirm current availability with our team.
Ҳуҷҷатҳо ва маводҳо
Дастур оид ба истифода (IFU), варақаҳои техникӣ ва адабиёти клиникӣ барои Masters Series Mechanical Heart Valve аз рӯи дархост аз дастаи клиникии мо дастрас аст.
Дархости ҳуҷҷатҳоСаволҳои зуд-зуд додашаванда
- What is the Masters Series Mechanical Heart Valve?
- The Masters Series mechanical heart valves are rotatable, bileaflet valves designed for implantation in the aortic or mitral position. Abbott minimizes valve bulk with the sleek Pivot Guard design paired with sewing-cuff options that maximize implantability without extraneous material.
- What is the 15 mm Masters HP valve?
- The 15 mm Masters HP Mitral and Aortic Valve is the world's smallest mechanical heart valve. It makes it possible to treat the tiniest patients, including newborns and babies, and is available as models 15AHPJ-505 (aortic) and 15MHPJ-505 (mitral).
- How was the Masters Series designed to reduce thrombogenicity?
- The Masters Series was designed with low thrombogenicity at the forefront: minimized carbon surface area can lessen thrombus formation, large internal diameters up to 26.1 mm promote low pressure gradients that can help minimize shear stress and thrombogenicity, and uniform velocities within the hinge recesses help aid washout of blood elements.
- What cuff options are available in the Masters Series?
- The Masters Series offers a broad range of cuff options to tailor implantation to every patient — including HP standard and expanded cuffs (xxAHPJ-505 / xxAEHPJ-505 aortic, xxMHPJ-505 mitral), polyester standard and expanded cuffs (xxAJ-501 / xxAECJ-502 aortic, xxMJ-501 / xxMECJ-502 mitral), and PTFE cuffs (xxATJ-503 aortic, xxMTJ-503 mitral, xxMETJ-504 expanded PTFE mitral).