Abbott Tendyne transcatheter mitral valve replacement system
Repositionable, retrievable transcatheter mitral valve replacement (TMVR) system · Технологияҳои транскатетерии клапанҳо

Tendyne™ (TMVR system)Рамзи маҳсулот (REF): TENDV-SP-39M

Tendyne™ transcatheter mitral valve replacement (TMVR) improves patients' function and quality of life by offering select patients with symptomatic, significant MR (≥ grade 3) a less invasive mitral valve replacement option over conventional mitral valve surgery. Tendyne TMVR provides symptom relief by eliminating MR, and is performed as a beating-heart procedure without the need for cardiopulmonary bypass or rapid pacing. Reported clinical outcomes include complete MR elimination in 99% of patients at 30 days, sustained MR elimination in 93% of patients at 2 years, a 96% technical success rate (per Mitral Valve Academic Research Consortium, MVARC), significant improvement in symptom and quality-of-life measures, and a low mean mitral gradient of 3.2 mm Hg at 2 years. The system is fully repositionable and retrievable at any point intraprocedurally. The Tendyne™ valve is designed for the mitral anatomy to eliminate MR and is supplied in SP and LP models across a range of valve numbers — 39M, 29S, 29L, 33S and 35M — with device AP dimensions from 29.0 to 38.5 mm and effective orifice areas up to 3.0 cm². The implantation and retrieval system comprises the Tendyne™ loading, delivery, pad position and Gen 2 retrieval systems; the delivery and retrieval systems use a 36 F sheath ID.

Таҳти рамзҳои маҳсулот TENDV-SP-39M, TENDV-LP-29S, TENDV-LP-29L, TENDV-LP-33S, TENDV-LP-35M дастрас аст.

Андозаҳо ва хусусиятҳо

Therapy
Transcatheter mitral valve replacement (TMVR)
Valve models
SP (39M) and LP (29S, 29L, 33S, 35M)
Device AP
29.0–38.5 mm
Effective orifice area
2.2–3.0 cm²
Delivery/retrieval sheath ID
36 F

Истеҳсолкунанда: Abbott Laboratories · Манбаи маълумот: cardiovascular.abbott

Тарҳ ва технология

Хусусиятҳои техникӣ ва диаграммаҳо тибқи нашрияҳои Abbott.

Designed for the mitral anatomy to eliminate MR

Official Abbott labelled graphic of the Tendyne mitral valve parts

Муайянкунӣ ва хусусиятҳои маҳсулот

Идентификаторҳои истинодӣ барои харид, бақайдгирӣ ва ҳуҷҷатҳои тендерӣ.

Рамзи маҳсулотTENDV-SP-39M
Рақами REFTENDV-SP-39M, TENDV-LP-29S, TENDV-LP-29L, TENDV-LP-33S, TENDV-LP-35M
ИстеҳсолкунандаAbbott Laboratories
БрендAbbott
Оилаи маҳсулотТехнологияҳои транскатетерии клапанҳо
Дастрасӣ аз рӯи кишварҳоТоҷикистон, Афғонистон

Истифодаи клиникӣ

Tendyne™ (TMVR system) як repositionable, retrievable transcatheter mitral valve replacement (tmvr) system аз оилаи «Технологияҳои транскатетерии клапанҳо»-и истеҳсоли Abbott Laboratories мебошад, ки аз ҷониби мутахассисони мудохилавӣ дар просессҳое истифода мешавад, ки дар онҳо repositionable, retrievable transcatheter mitral valve replacement (tmvr) system-и ин синф нишон дода шудааст. Он дар 5 конфигуратсия (рамзҳои каталогӣ аз TENDV-SP-39M то TENDV-LP-35M) барои мутобиқат бо талаботи анатомӣ ва просессӣ пешниҳод мешавад.

Барои нишондодҳои пурраи истифода, зидди нишондодҳо ва дастур оид ба истифода (IFU) ҳуҷҷатҳои расмии Abbott-ро тавассути дастаи клиникии мо дархост кунед. Modern Medical Solutions Tendyne™ (TMVR system)-ро ба беморхонаҳо ва лабораторияҳои катетеризатсионӣ дар саросари Тоҷикистон ва Афғонистон таъмин мекунад.

Маълумот барои фармоиш

Рамзҳои истинодии каталогӣ тибқи нашрияҳои Abbott. Барои тасдиқи мавҷудияти ҷорӣ бо мо тамос гиред.

ModelSP
Valve Number39M
Catalog NumberTENDV-SP-39M
Device AP (mm)38.5
Device IC (mm)50.5
Device Perimeter (mm)156
EOA (cm²)3.0
ModelLP
Valve Number29S
Catalog NumberTENDV-LP-29S
Device AP (mm)29.0
Device IC (mm)42.5
Device Perimeter (mm)119
EOA (cm²)2.2
ModelLP
Valve Number29L
Catalog NumberTENDV-LP-29L
Device AP (mm)29.0
Device IC (mm)47.5
Device Perimeter (mm)129
EOA (cm²)
ModelLP
Valve Number33S
Catalog NumberTENDV-LP-33S
Device AP (mm)32.5
Device IC (mm)43.5
Device Perimeter (mm)130
EOA (cm²)
ModelLP
Valve Number35M
Catalog NumberTENDV-LP-35M
Device AP (mm)34.5
Device IC (mm)48.5
Device Perimeter (mm)144
EOA (cm²)

Model, valve number and catalog numbers transcribed from the Abbott Tendyne™ TMVR Ordering Information section (valve product specifications and implantation/retrieval system). Item approved for OUS use only.

Ҳуҷҷатҳо ва маводҳо

Дастур оид ба истифода (IFU), варақаҳои техникӣ ва адабиёти клиникӣ барои Tendyne™ (TMVR system) аз рӯи дархост аз дастаи клиникии мо дастрас аст.

Дархости ҳуҷҷатҳо

Саволҳои зуд-зуд додашаванда

Who is Tendyne™ TMVR intended for?
Tendyne™ transcatheter mitral valve replacement is intended for select patients with symptomatic, significant mitral regurgitation (MR ≥ grade 3), offering a less invasive mitral valve replacement option over conventional mitral valve surgery.
Is the Tendyne™ procedure performed on cardiopulmonary bypass?
No. Tendyne™ TMVR is a beating-heart procedure performed without the need for cardiopulmonary bypass or rapid pacing. The system is also fully repositionable and retrievable at any point intraprocedurally.
What are the reported clinical outcomes for Tendyne™?
Reported outcomes include complete MR elimination in 99% of patients at 30 days, sustained MR elimination in 93% of patients at 2 years, a 96% technical success rate (per MVARC), and a low mean mitral gradient of 3.2 mm Hg at 2 years, with significant improvement in symptom and quality-of-life measures.
What valve sizes and delivery components are available?
The valve is supplied in SP (39M) and LP (29S, 29L, 33S, 35M) models with device AP dimensions from 29.0 to 38.5 mm and EOA up to 3.0 cm². The implantation and retrieval system includes the Tendyne™ loading system (TENDV-LS), delivery system (TENDV-DS), pad position system (TENDV-PS) and Gen 2 retrieval system (TENDV-RS2); the delivery and retrieval systems use a 36 F sheath ID.

Марбут дар «Технологияҳои транскатетерии клапанҳо»